C1DA--A/E Services Replace Patient Lifts B331, B348, & B360 Project Number: 640A0-27-103

261-Network Contract Office 21 (36C261) · United States government procurement

Closed September 28, 2026. GlobalGov surfaces government procurement from around the world, including the markets your competitors overlook.

Closed
Status

Opportunity Overview

This is a Call for SF 330s. Please read the entire document.

The Department of Veterans Affairs VA Palo Alto Menlo Park Healthcare System, CA is seeking Architectural/Engineering Firms to submit Standard Form (SF) 330 for Project 640A0-27-103, Replace Patient Lifts B331, B348, & B360. The project will be located at the Palo Alto Menlo Park VA Campus, 3801 Miranda Ave, Palo Alto, California 94304.

DESCRIPTION OF REQUIREMENT

The VA Palo Alto - Menlo Park Division needs A/E design services to replace/install 141 new ceiling-mounted patient lifts and extend 24 existing lifts for full room + bathroom coverage in CLC Buildings 331, 348, and 360. B348/B360 private rooms have no lift; B331 has outdated linear lifts; B360 needs bathroom coverage extensions + 30 motor upgrades. A/E Requirement: Full field survey above/below ceiling, structural/SE seismic analysis and HCAI OPM, MEP/electrical, fire protection, phasing plan for occupied patient rooms, Revit BIM, specs, and independent cost estimate. Construction cost shall not exceed $16.4M for all work in B331, B348 & B360, requiring site investigations, block diagrams, and full design deliverables at 35%, 65%, 95%, 100% and final production per VA Master Specs and all applicable codes, including cost estimates, phased construction documents, and 5-year construction period services including RFI responses, submittal reviews, weekly meetings, site inspections, and as-builts, all to be completed within a 266-day design period.

The design shall also substantially meet the VA design criteria as listed in VA design guides and manuals, which can be found on the web at the VA Office of Facilities Management technical information library site address: http://www.cfm.va.gov/TIL

The design effort shall also include review of and assurance of compliance with the National Environmental Policy Act, including development and submission of all documents, reports, and activities necessary to obtain the required compliance.

The contract...

Your competitors are watching the same crowded contracts everyone else is. Track live opportunities like this one worldwide, set deadline alerts, and win where they aren’t. Free for 14 days, no card.

Start Free

Solicitation Details

Issuing agency261-Network Contract Office 21 (36C261)
CountryUnited States
CategoryGovernment Procurement
NAICS541330
PSCC1DA
PublishedAugust 28, 2026
Procurement stageActive solicitation
ClosedSeptember 28, 2026
StatusClosed — no longer accepting responses
Official sourceView original notice
Last verifiedOctober 10, 2026

Source: U.S. Government (SAM.gov) — public domain. GlobalGov is not affiliated with or endorsed by the United States Government.

Browse Similar Open Opportunities in United States

Z2DA--Replace Bldg. 700 UPS | project 612A4-27-040 | Mather CA
Z2LZ--Design Build to Install Parking Shades and Parking Lot Reconfiguration Project 593-26-306
J061--Triennial Circuit Breaker and Feeder Testing
6630 - Brand Name or Equal COPAN Walk-Away Specimen Processor (WASP)
V999--Office move
J065 | Viewpoint Software Support and Maintenance
Residential Treatment Services for SFVAHCS
Z2DA--Construction Project 570-25-314 Replace Surgical Air Handler Unit (AHU)

See every United States Government Procurement opportunity your competition is missing. Free for 14 days.

Get real-time alerts, competitive intelligence, and deadline tracking for this and every market worldwide.

Start Free Trial — No Card Required

Free 14-day trial · no card required

See who is already competing here →

Get a free United States Government Procurement intelligence report in your inbox

A personalized report on United States Government Procurement opportunities, emailed in 5-10 minutes. One per month, no account needed.