Eaton Powerware System Replacement

241-Network Contract Office 01 (36C241) · United States government procurement

Get new United States Technology tenders by email, free: Set up alerts

GlobalGov surfaces government procurement from around the world, including the markets your competitors overlook.

November 30, 2026
Response Due
Active
Status

Want more tenders like this one?

We will email you a free list of open Technology tenders in the United States, usually within 10 minutes. No account needed.

Opportunity Overview

36C24127Q0030 UPS Eaton Powerware System Replacement - RFIs Does the VA require technicians performing quarterly and annual preventive maintenance to be individually factory-certified or authorized by Eaton? Due to the complex nature of the product and criticality - Yes Will documented experience and technical qualifications satisfy the qualification requirement for routine preventive maintenance? See answer to RFI 1 Is direct access to Eaton's proprietary field-service software mandatory for the prime contractor, or may that requirement be fulfilled through an Eaton-authorized service provider supporting specific procedures? Prime Contractor does not require that; That portion can be filled through an Eaton Authorized Technician. Would a contractor be considered technically acceptable if it performs routine maintenance using qualified technicians and subcontracts manufacturer-restricted procedures and startup to Eaton? Yes, minor PM work such as filter changes etc. would be outside the requirement of needing an Eaton Technician. Since Eaton has discontinued the 93E product line, will the VA accept the current Eaton 93PM or another equivalent replacement system meeting the required performance specifications? The VA would accept an Eaton alternative. The goal of the project is to replace existing equipment in-kind with newer model. Does the existing Eaton Powerware 9390 system have an external maintenance bypass (for example, a maintenance bypass panel or a bypass sidecar with maintenance bypass and isolation breakers)? Yes, See photos. Is the replacement expected to include a maintenance bypass sidecar, such as the Eaton 93E 60 kVA bypass sidecar shown in Attachment A, or is it limited to the UPS and Extended Battery Cabinet listed in SOW Section 3.5? The UPS is required to be able to go into maintenance Bypass and maintain power to the computer room during maintenance. What is the kVA rating of the existing unit? The SOW says "Model 80," but the replacement is...

Tenders like this are published on a national procurement portal that most bidders outside the United States never check.

How to bid: GlobalGov tracks this tender; it does not accept bids. Submit your response through the issuing agency’s official notice.

Bidding on this? Book 15 minutes with us and we will pull the documents, past awards and a translation for this tender live with you. Book a walkthrough

Your competitors are watching the same crowded contracts everyone else is. Track this opportunity and every one like it worldwide, set deadline alerts, and win where they aren’t. Free for 14 days, cancel anytime.

Start a free GlobalGov account

Solicitation Details

Issuing agency241-Network Contract Office 01 (36C241)
CountryUnited States
CategoryTechnology
NAICS811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
PSCJ061
PublishedNovember 24, 2026
Procurement stageRequest for Proposal (RFP)
Response dueNovember 30, 2026
StatusOpen — accepting responses
Official sourceView original notice Track this tender · Get the tender pack: $49, delivered within 24h
Last verifiedNovember 28, 2026

Source: U.S. Government (SAM.gov) — public domain. GlobalGov is not affiliated with or endorsed by the United States Government.

Related Opportunities in United States

Euro-Diesel DRUPS (Diesel Rotary Uninterruptible Power Supply)
Capstan Maintenance Services at Naval Support Activity (NSA), Portsmouth, Virginia
Oerlikon Metco Thermal Spray Equipment
Dry-Type Fire Suppression System
LLA Fish Pump - Motor Rewind
Generator Maintenance and Inspection Services in Embassy Compound and Residences - U.S. Embassy Majuro, Marshall Islands
Hydrostatic Testing
Blanket Purchase Agreement (BPA) for CNC Machine Repair, Parts, Programming, and Training Services Blue Grass Army Depot (BGAD)

See every United States Technology opportunity your competition is missing. Free for 14 days.

Get real-time alerts, competitive intelligence, and deadline tracking for this and every market worldwide.

Start Your 14-Day Free Trial

Free 14-day trial · cancel anytime

See who is already competing here →